APPENDIX E SERIAL COMMANDS
114
Flow Control
DESCRIPTION:
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.
BINARY FORM DETAILS
COMMAND FORM: <Header><Argument 1>
COMMAND ID: 15
ARGUMENT SIZE: 1 word
ARGUMENT FORM:
Name: <Value>
Size 32 bits
Type Unsigned integer
Range/value 0 - 2
RETURN VALUES:
Unit always returns the last executed flow control selection in the same form as above.
TEXT FORM DETAILS
COMMAND FORM <DEVICE> FLOW [Value]
Where:
DEVICE: See General Text command form Description
FLOW Text Command
Value
0 disable flow control
1 enable hardware flow control
2 to toggle
Null return the current flow control setting
RETURN VALUES
The command will return the updated condition of flow control in the same format as the command.
If Command Returns
Flow control is disabled DEVICE FLOW 0
Flow control is set to hardware (DTR/DSR) DEVICE FLOW 1